Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix MV600/V620 ID Controller Protocol
397
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note 1. Execute Sequence No. 532 before executing Sequence No. 533.
2. Retry processing is not performed for this sequence.
Polling Auto-write (Hexadecimal/2) (Sequence No. 534)
This sequence is used when the number of Heads to be written to the Carrier is 2.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of Sequence No. 523 (Write (Hexadecimal/2)).
Receive Data Word Allocation (3rd Operand of PMCR)
The receive data word allocation is similar to that of Sequence No. 523 (Write (Hexadecimal/2)).
Note 1. Execute Sequence No. 545 (Polling Auto-write Command Processing Cancel) to cancel the polling
auto-write.
2. Retry processing is not performed for this sequence.
Polling Auto-write Subcommand (Hexadecimal/2) (Sequence
No. 535)
This sequence is used when the number of Heads to be written to the Carrier is 2. Up to 56 digits of data can be
written for each Read/Write Head.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of Sequence No. 523 (Write (Hexadecimal/2)). However, the lead-
ing address No., number of write, and write data are not used and become undefined.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note 1. Execute Sequence No. 534 before executing Sequence No. 535.
2. Retry processing is not performed for this sequence.
Polling Auto-write (Hexadecimal/4) (Sequence No. 536)
This sequence is used when the number of Heads to be written to the Carrier is 4.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of Sequence No. 524 (Write (Hexadecimal/4)).
Receive Data Word Allocation (3rd Operand of PMCR)
The receive data word allocation is similar to that of Sequence No. 524 (Write (Hexadecimal/4)).
Note 1. Execute Sequence No. 545 (Polling Auto-write Command Processing Cancel) to cancel the polling
auto-write.
2. Retry processing is not performed for this sequence.
Polling Auto-write Subcommand (Hexadecimal/4) (Sequence
No. 537)
This sequence is used when the number of Heads to be written to the Carrier is 2. Up to 24 digits of data can be
written for each Read/Write Head.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of Sequence No. 524 (Write (Hexadecimal/4)). However, the lead-
ing address No., number of write, and write data are not used and become undefined.
Receive Data Word Allocation (3rd Operand of PMCR)
None.