Write (Hexadecimal/1) (Sequence No. 522)
This sequence is used when the number of Heads to be written to the Carrier is 1.
Send Data Word Allocation (2nd Operand of PMCR)
First word of send
data
+0
+1
+2
+3
+4
+5
Max +35
Number of send data words
(Undefined)
Unit No.
(Undefined)
Head CH No.
Leading address No.
Number of write digits
~ ~
(Undefined)
Write data
Write data
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0006 to 0036
+1 Relevant Unit No. (2 digits BCD) 00 to 07 (CD1D)
00 to 15 (CA2A)
+2 R/W Head CH No. (1 digit BCD) R/W Head CH 1 designation: 1
R/W Head CH 2 designation: 2
The CD1D must be set to 1.
+3 Leading address No.
(4 digits Hexadecimal)
0000 to FFFF
+4 Number of write digits
(4 digits BCD)
0002 to 0122
+5 to
35
Write data (Hexadecimal) Input in hexadecimal
Up to 122 digits (max.)
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note 1. Data of which Data Carrier designated for hexadecimal is sent beginning with the largest offset from the
send data words.
2. Always set an even number of digits for the write data.