Appendix FE5ZE Temperature Controller Write Protocol
221
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0018 (fixed)
+1 Unit No. (2 digits Hex) 00 to 0F
+2 Channel 0
Output value (4 digits BCD)
0000 to 1000
+3 Channel 0
Cooling output value
(4 digits BCD)
0000 to 1000
+4 Channel 1
Output value (4 digits BCD)
0000 to 1000
+5 Channel 1
Cooling output value
(4 digits BCD)
0000 to 1000
D
D
D
+16 Channel 7
Output value (4 digits BCD)
0000 to 1000
+17 Channel 7
Cooling output value
(4 digits BCD)
0000 to 1000
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Write Output Value Limit (Sequence No. 166)
Writes the output value limits that restrict the values of the control outputs.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Number of send data words+0
+1
+2
+3
+4
+5
+30
+31
+32
+33
(Undefined)
Unit No.
Output value lower limit
~ ~
Output value upper limit
Output value lower limit
Output value upper limit
Channel 0
Channel 7
Cooling output value lower limit
Cooling output value upper limit
Cooling output value lower limit
Cooling output value upper limit