Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix G
E5jJ Temperature Controller Protocol
235
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
Number of units 4 + 2
+1 Number of units (4 digits BCD) 0001 to 0031
+2 1st unit Unit No. (2 digits BCD) 00 to 31
+3 1st unit
Proportional band (4 digits BCD)
0000 to 9999
+4 1st unit
Integral time (4 digits BCD)
0000 to 9999
+5 1st unit
Derivative time (4 digits BCD)
0000 to 9999
+6 2nd unit
Unit No. (2 digits BCD)
00 to 31
D
D
D
+125
(max.)
31th unit
Derivative time (4 digits BCD)
0000 to 9999
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Write Input Shift Value (Sequence No. 207)
Writes the input shift value.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Number of send data words+0
+1
+2
(Undefined)
Unit No.
Input shift value
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0003 (fixed)
+1 Unit No. (2 digits BCD) 00 to 31
+2 Input shift value (4 digits BCD) 0000 to 9999
Receive Data Word Allocation (3rd Operand of PMCR)
None