Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix MV600/V620 ID Controller Protocol
368
Sequence
No.
Ladder interfaceFunctionCommunications
sequence name
Sequence
No.
Receive word
allocation
Send word
allocation
FunctionCommunications
sequence name
519 Write (ASCII/2) Used when the number of Heads to be written
to the Carrier is 2.
Yes No
520 Write (ASCII/4) Used when the maximum number of Heads to
be written to the Carrier is 4.
Yes No
521 Write (ASCII/8) Used when the maximum number of Heads to
be written to the Carrier is 8.
Yes No
522 Write (Hexadeci-
mal/1)
Used when the number of Heads to be written
to the Carrier is 1.
Yes No
523 Write (Hexadeci-
mal/2)
Used when the number of Heads to be written
to the Carrier is 2.
Yes No
524 Write (Hexadeci-
mal/4)
Used when the maximum number of Heads to
be written to the Carrier is 4.
Yes No
525 Write (Hexadeci-
mal/8)
Used when the maximum number of Heads to
be written to the Carrier is 8.
Yes No
526 Auto-write (ASCII/1) Used when the number of Heads to be written
to the Carrier is 1.
Yes No
527 Auto-write (Hexade-
cimal/1)
Used when the number of Heads to be written
to the Carrier is 1.
Yes No
528 Polling Auto-write
(ASCII/2)
Used when the number of Heads to be written
to the Carrier is 2.
Yes No
529 Polling Auto-write
Subcommand
(ASCII/2)
Used when the number of Heads to be written
to the Carrier is 2.
Yes No
530 Polling Auto-write
(ASCII/4)
Used when the maximum number of Heads to
be written to the Carrier is 4.
Yes No
531 Polling Auto-write
Subcommand
(ASCII/4)
Used when the maximum number of Heads to
be written to the Carrier is 4.
Yes No
532 Polling Auto-write
(ASCII/8)
Used when the maximum number of Heads to
be written to the Carrier is 8.
Yes No
533 Polling Auto-write
Subcommand
(ASCII/8)
Used when the maximum number of Heads to
be written to the Carrier is 8.
Yes No
534 Polling Auto-write
(Hexadecimal/2)
Used when the number of Heads to be written
to the Carrier is 2.
Yes No
535 Polling Auto-write
Subcommand (Hexa-
decimal/2)
Used when the number of Heads to be written
to the Carrier is 2.
Yes No
536 Polling Auto-write
(Hexadecimal/4)
Used when the maximum number of Heads to
be written to the Carrier is 4.
Yes No
537 Polling Auto-write
Subcommand (Hexa-
decimal/4)
Used when the maximum number of Heads to
be written to the Carrier is 4.
Yes No
538 Polling Auto-write
(Hexadecimal/8)
Used when the maximum number of Heads to
be written to the Carrier is 8.
Yes No
539 Polling Auto-write
Subcommand (Hexa-
decimal/8)
Used when the maximum number of Heads to
be written to the Carrier is 8.
Yes No
540 Data check Writes and verify the CRC code for the check
blocks designated by the user.
Yes Yes
541 Control management Performs I/O or an I/O read. Yes Yes
542 Error information
read
Reads information from the latest error log. Yes Yes
543 Command proces-
sing cancel
Cancels command processing except polling
command processing and returns to the com-
mand waiting status.
Yes Yes