Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix H
ES100j Digital Controller Protocol
248
Receive Data Word Allocation (3rd Operand of PMCR)
Time signal 1
Time signal 9
Time signal 2
Receive data
storage words
Number of receive data words+0
+1
+2
+3
+4
+5
+121
+122
+123
+124
+125
Time signal 1
~ ~
1st unit
25th unit (max.)
Time signal 2
Time signal 3 Time signal 4
Time signal 5 Time signal 6
Time signal 7 Time signal 8
Time signal 10
Time signal 3 Time signal 4
Time signal 5 Time signal 6
Time signal 7 Time signal 8
Time signal 9 Time signal 10
Offset Contents (data format) Data
+0 Number of receive data words
(4digits BCD)
Number of units 5 + 1
+1 1st unit
Time signal 1 data (2 digits Hex)
Time signal 2 data (2 digits Hex)
00 to FF
00 to FF
+2 1st unit
Time signal 3 data (2 digits Hex)
Time signal 4 data (2 digits Hex)
00 to FF
00 to FF
+3 1st unit
Time signal 5 data (2 digits Hex)
Time signal 6 data (2 digits Hex)
00 to FF
00 to FF
+4 1st unit
Time signal 7 data (2 digits Hex)
Time signal 8 data (2 digits Hex)
00 to FF
00 to FF
+5 1st unit
Time signal 9 data (2 digits Hex)
Time signal 10 data (2 digits Hex)
00 to FF
00 to FF
D
D
D
+125
(max.)
25th unit
Time signal 9 data (2 digits Hex)
Time signal 10 data (2 digits Hex)
00 to FF
00 to FF
Read Error Detection Data (Sequence No. 252)
Reads error groups from 0 to 15 in the variable area.
Send Data Word Allocation (2nd Operand of PMCR)
(Undefined)
Unit No.
First word of
send data
Number of send data words+0
+1
+2
+3
+17
(Undefined)
Unit No.
Number of units
(Undefined)
Unit No.
~ ~
16th unit (max.)
2nd unit
1st unit