Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix K3Z4L Laser Micrometer Protocol
337
AVG Move Interval Set (3000-series, High-speed Type)
(Sequence No. 424)
This sequence uses the average move as the averaging method and sets the measurement interval number.
Send Data Word Allocation (2nd Operand of PMCR)
First word of send
data
Number of send data words+0
+1
(Undefined)
Measurement interval number
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0002 (fixed)
+1 Measurement interval number
(1 digit BCD)
1 to 4
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.
AVG Move (H) Times Set (3000-series, High-speed Type)
(Sequence No. 425)
This sequence uses the average move and high-speed data output as the averaging method and sets the averag-
ing times per measurement interval 4.
Send Data Word Allocation (2nd Operand of PMCR)
First word of send
data
Number of send data words+0
+1
Number of averaging times
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0002 (fixed)
+1 Number of averaging times
(4 digits BCD)
16 to 2048
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.
AVG Move (L) Times Set (3000-series, High-speed Type)
(Sequence No. 426)
This sequence uses the average move and low-speed data output as the averaging method and sets the averag-
ing times per measurement interval 4.
Send Data Word Allocation (2nd Operand of PMCR)
First word of send
data
Number of send data words+0
+1
Number of averaging times
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0002 (fixed)
+1 Number of averaging times
(4 digits BCD)
32 to 2048
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.