Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix MV600/V620 ID Controller Protocol
384
Polling Auto-read Sub-command (ASCII/2) (Sequence No. 511)
This sequence is used when the maximum number of Heads to be read from the Carrier is 2. Up to 118 bytes of
data can be read for each Read/Write Head.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of Sequence No. 501 (Read (ASCII/2)). However, the leading ad-
dress No. and number of read bytes are not used and will be the value specified for sequence #510.
Receive Data Word Allocation (3rd Operand of PMCR)
The receive data word allocation is similar to that of Sequence No. 501 (Read (ASCII/2)).
Note 1. Execute Sequence No. 510 before executing Sequence No. 511.
2. Data from Data Carriers designated for ASCII is stored beginning with the smallest offset from the re-
ceive data words.
3. Retry processing is not performed for this sequence.
Polling Auto-read Sub-command (ASCII/4) (Sequence No. 512)
This sequence is used when the maximum number of Heads to be read from the Carrier is 4. Up to 48 bytes of data
can be read for each Read/Write Head.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of Sequence No. 502 (Read (ASCII/4)). However, the leading ad-
dress No. and number of read bytes are not used and will be the value specified for sequence #510.
Receive Data Word Allocation (3rd Operand of PMCR)
The receive data word allocation is similar to that of Sequence No. 502 (Read (ASCII/4)).
Note 1. Execute Sequence No. 510 before executing Sequence No. 512.
2. Data from Data Carriers designated for ASCII is stored beginning with the smallest offset from the re-
ceive data words.
3. Retry processing is not performed for this sequence.
Polling Auto-read Sub-command (ASCII/8) (Sequence No. 513)
This sequence is used when the maximum number of Heads to be read from the Carrier is 8. Up to 20 bytes of data
can be read for each Read/Write Head.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of Sequence No. 503 (Read (ASCII/8)). However, the leading ad-
dress No. and number of read bytes are not used and will be the value specified for sequence #510.
Receive Data Word Allocation (3rd Operand of PMCR)
The receive data word allocation is similar to that of Sequence No. 503 (Read (ASCII/8)).
Note 1. Execute Sequence No. 510 before executing Sequence No. 513.
2. Data from Data Carriers designated for ASCII is stored beginning with the smallest offset from the re-
ceive data words.
3. Retry processing is not performed for this sequence.