Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix EE5ZE Temperature Controller Read Protocol
203
Read Present Set Point (Sequence No. 116)
Reads the present set points during ramp operation and stores the results in the specified word.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Number of send data words+0
+1
(Undefined)
Unit No.
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0002 (fixed)
+1 Unit No. (2 digits Hex) 00 to 0F
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
Number of receive data words+0
+1
+2
+15
+16
Present set point (rightmost 4 digits)
~ ~
Present set point (leftmost 1 digit)
Present set point (rightmost 4 digits)
Present set point (leftmost 1 digit)
Channel 0
Channel 7
Offset Contents (data format) Data
+0 Number of receive data words
(4 digits BCD)
0017
+1 Channel 0
Present set point (rightmost 4 digits)
(4 digits BCD)
Varies according to the temperature sensor
type. Refer to the manual for the E5ZE.
+2 Channel 0
Present set point (leftmost 1 digit)
(1 digit BCD)
F indicates a negative value.
D
D
D
+15 Channel 7
Present set point (rightmost 4 digits)
(4 digits BCD)
Varies according to the temperature sensor
type. Refer to the manual for the E5ZE.
+16 Channel 7
Present set point (leftmost 1 digit)
(1 digit BCD)
F indicates a negative value.
Read Output Value Limit (Sequence No. 117)
Reads the output value limits and stores the results in the specified words.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Number of send data words+0
+1
(Undefined)
Unit No.
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0002 (fixed)
+1 Unit No. (2 digits Hex) 00 to 0F