Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix MV600/V620 ID Controller Protocol
386
2. Data from Data Carrier designated for hexadecimal is stored beginning with the largest offset from the
receive data words.
3. Retry processing is not performed for this sequence.
Polling Auto-read Sub-command (Hexadecimal/4) (Sequence
No. 516)
This sequence is used when the maximum number of Heads to be read from the Carrier is 4. Up to 24 bytes of data
can be read for each Read/Write Head.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of Sequence No. 506 (Read (Hexadecimal/4)). However, the lead-
ing address No. and number of read bytes are not used and will be the value specified for sequence #514.
Receive Data Word Allocation (3rd Operand of PMCR)
The receive data word allocation is similar to that of Sequence No. 506 (Read (Hexadecimal/4)).
Note 1. Execute Sequence No. 514 before executing Sequence No. 516.
2. Data from Data Carrier designated for hexadecimal is stored beginning with the largest offset from the
receive data words.
Polling Auto-read Sub-command (Hexadecimal/8) (Sequence
No.517)
This sequence is used when the maximum number of Heads to be read from the Carrier is 8. Up to 10 bytes of data
can be read for each Read/Write Head.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of sequence No.507 (Read (Hexadecimal/8)). However, the leading
address No. and number of read bytes are not used and will be the value specified for sequence #514.
Receive Data Word Allocation (3rd Operand of PMCR)
The receive data word allocation is similar to that of sequence No.507 (Read (Hexadecimal/8)).
Note 1. Execute sequence No.514 before executing sequence No.517.
2. Data from Data Carriers designated for hexadecimal is stored beginning with the largest offset from the
receive data words.
3. Retry processing is not performed for this sequence.
Write (ASCII/1) (Sequence No.518)
This sequence is used when the number of Heads to be written to the Carrier is 1.
Send Data Word Allocation (2nd Operand of PMCR)
First word of send
data
Number of send data words+0
+1
+2
+3
+4
+5
Max
+128
(Undefined)
Unit No.
(Undefined)
Unit No.
(Undefined)
Head CH No.
Leading address No.
Number of write bytes
Write data
~ ~
Write data