Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix K3Z4L Laser Micrometer Protocol
345
Continuous Measurement Termination (4000-series)
(Sequence No. 438)
This sequence terminates continuous measurement.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
For continuous measurement: None.
For Deflection Measurement
The receive data word allocation is similar to that of sequence No. 434 (Single Run Measurement Start).
Data Request (4000-series) (Sequence No. 439)
This sequence requests display data in the idle measurement status or latch data generated by the measurement
command.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
The receive data word allocation is similar to that of sequence No. 434 (Single Run Measurement Start).
Forced Positive Zero (4000-series) (Sequence No. 440)
This sequence sets the forced zero direction to positive (+)
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Forced Negative Zero (4000-series) (Sequence No. 441)
This sequence sets the forced zero direction to negative ()
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Forced Zero Release (4000-series) (Sequence No. 442)
This sequence releases the forced zero direction.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
3Z4L Initialize (4000-series) (Sequence No. 443)
This sequence clears the 3Z4L, sets the mm unit, and sets memory switches.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of sequence No. 401 (Memory Switch Setting).
Receive Data Word Allocation (3rd Operand of PMCR)
None.