Appendix K3Z4L Laser Micrometer Protocol
339
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
Number of receive data words+0
+1
+2
+3
+4
+5
+6
+7
+8
(Undefined)
Invalid time
Decimal portion
(Undefined) Integer portion
Sign (Undefined)
Decimal portion
(Undefined) Integer portion
Sign (Undefined)
The number of measuring times
Detection lower limit
Detection upper limit
Offset Contents (data format) Data
+0 Number of receive data
words (4 digits BCD)
0009 (fixed)
+1 The number of measuring
times
(3 digits BCD)
000 to 999
+2 Invalid time
(4 digits BCD)
0001 to 9999
+3 Detection lower limit
(decimal portion)
(4 digits BCD)
0000 to 9999
4 5 6 7+3
Example –123.4567
+4 Detection lower limit
(integer portion)
(3 digits BCD)
000 to 999
0 1 2 3
F 0 0 0
+4
+5
+5 Detection lower limit (Sign)
(BIN)
If +: 0
If –: F
+6 to
+8
Detection upper limit Same as detection lower limit
Note This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.
3Z4L Initialize (3000-series) (Sequence No. 430)
This sequence clears the 3Z4L, sets the mm unit, sets memory switches, does not process statistics, and clears
the statistic memory.
Send Data Word Allocation (2nd Operand of PMCR)
The send data word allocation is similar to that of sequence No. 401 (Memory Switch Setting)
Receive Data Word Allocation (3rd Operand of PMCR)
None.