Omron CQM1H-SCB41 Computer Hardware User Manual


 
Appendix K3Z4L Laser Micrometer Protocol
327
Offset DataContents (data format)
+30 to
+32
Reference value Same as lower limit values
+33 Analog output scale number
(1 digit BCD)
1 to 3
+34 to
+35
Offset classification (ASCII
3 characters)
4F4620 (OF), 4F4D20 (OM)
+36 to
+38
Offset value Same as lower limit values
+39 Data output conditions
(1 digit BCD)
0 to 6
+40 Scheduled output timer
(3 digits BCD)
000 to 999
+41 Sample measurement pulse
(3 digits BCD)
000 to 999
+42 to
+43
Sample measurement
classification
(ASCII 3 characters)
415647 (AVG), 4D4158 (MAX)
4D494E (MIN), 524E47 (RNG)
+44 to
+45
Unused Undefined
+46 Yes/No for segment setting
(1 digit BCD)
Set: 1 (SG)
Dont set: 0
+47 Yes/No for measurement
interval number setting
(1 digit BCD)
Set: 1 (M)
Dont set: 0
+48 Yes/No for upper/lower limit
value setting
(1 digit BCD)
Set: 1 (LL,LH)
Dont set: 0
+49 Yes/No for multistep
selection limit value
(1 digit BCD)
Set: 1 (L1,L2,L3,L4,L5,L6)
Dont set: 0
+50 Yes/No for reference setting
(1 digit BCD)
Set: 1 (REF, SCL)
Dont set: 0
+51 Yes/No for offset value
setting (1 digit BCD)
Set: 1 (OF or OM)
Dont set: 0
+52 Yes/No for data output
condition setting
(1 digit BCD)
Set: 1 (PR, PRT)
Dont set: 0
+53 Yes/No for sample
measurement pulse setting
(1 digit BCD)
Set: 1 (SMP, MAX or MIN or RNG or AVG)
Dont set: 0
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note 1. This sequence cannot be used to set the error lower limit (EL), error upper limit (EH), error exclusion
counter (CNT) of the error data exclusion function (centerless grinder function).
2. The following settings must be made together with this sequence; they cannot be set separately.
Lower limit, upper limit
Multistep selection limit
Reference value, analog output scale number
Data output conditions, scheduled print timer
3. The limit value, reference value, and offset value can be set to 3 digits for the integer portion and to 4 dig-
its for the decimal portion.