K3Tj Intelligent Signal Processor Protocol
The K3Tj Intelligent Signal Processor Protocol is used to make various settings or control remotely the Intelligent
Signal Processor connected to the Serial Communications Board via RS-232C or RS-422A/485 cable.
Protocol Configuration
The configuration of the K3Tj Intelligent Signal Processor Protocol is shown as follows:
Sequence Communications Function
Ladder interface
Notes
No. sequence name
Send word
allocation
Receive word
allocation
300 Reset (by unit number) Performs the same processing as
when an input is received on the
reset terminal.
Yes No
301 Reset (continuous units) Performs the same processing as
when an input is received on the
reset terminal.
Yes No
302 Write set value (by unit
number)
Writes the set value HH, H, L, or
LL.
Yes No See
Note1
303 Write set value HH (con-
tinuous units)
Writes the set value HH. Yes No See
Note1
304 Write set value H (con-
tinuous units)
Writes the set value H. Yes No See
Note1
305 Write set value L (contin-
uous units)
Writes the set value L. Yes No See
Note1
306 Write set value LL (con-
tinuous units)
Writes the set value LL. Yes No See
Note1
307 Write set value with bank
(by unit number)
Writes the set value to a bank
which is not in use (K3TR: HH to
LL, K3TC: O1 to O5).
Yes No See
Note2
308 Write set value HH with
bank (continuous units)
Writes the set value HH to a bank
which is not in use.
Yes No See
Note1
309 Write set value H with
bank (continuous units)
Writes the set value H to a bank
which is not in use.
Yes No See
Note1
310 Write set value L with
bank (continuous units)
Writes the set value L to a bank
which is not in use.
Yes No See
Note1
311 Write set value LL with
bank (continuous units)
Writes the set value LL to a bank
which is not in use.
Yes No See
Note1
312 Write set value O5 with
bank (continuous units)
Writes the set value O5 to a bank
which is not in use.
Yes No See
Note1
313 Write set value O4 with
bank (continuous units)
Writes the set value O4 to a bank
which is not in use.
Yes No See
Note1
314 Write set value O3 with
bank (continuous units)
Writes the set value O3 to a bank
which is not in use.
Yes No See
Note1
315 Write set value O2 with
bank (continuous units)
Writes the set value O2 to a bank
which is not in use.
Yes No See
Note1
316 Write set value O1 with
bank (continuous units)
Writes the set value O1 to a bank
which is not in use.
Yes No See
Note1
317 Read set value (by unit
number)
Reads the set value HH, H, L, or
LL.
Yes Yes See
Note1
318 Read set value HH (con-
tinuous units)
Reads the set value HH. Yes Yes See
Note1
319 Read set value H (con-
tinuous units)
Reads the set value H. Yes Yes See
Note1