Appendix K3Z4L Laser Micrometer Protocol
338
Automatic Detection Set (3000-series, High-speed Type)
(Sequence No. 427)
This sequence sets the work automatic detection function.
Send Data Word Allocation (2nd Operand of PMCR)
Receive data
storage words
Number of send data words+0
+1
+2
+3
+4
+5
+6
+7
+8
(Undefined)
Invalid time
Decimal portion
(Undefined) Integer portion
Sign (Undefined)
Decimal portion
(Undefined) Integer portion
Sign (Undefined)
The number of measuring times
Detection lower limit
Detection upper limit
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0009 (fixed)
+1 Number of measurements
(3 digits BCD)
001 to 999
+2 Invalid time (4 digits BCD) 0001 to 9999
+3 Detection lower limit
(decimal portion)
(4 digits BCD)
0000 to 9999
4 5 6 7+3
Example –123.4567
+4 Detection lower limit
(integer portion)
(3 digits BCD)
000 to 999
0 1 2 3
2 D 0 0
+4
+5
+5 Detection lower limit (Sign)
(ASCII 1 character)
If +: 20 (‘ ’)
If – : 2D (‘–’)
+6 to
+8
Detection upper limit Same as detection lower limit
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.
Automatic Detection Release (3000-series, High-speed Type)
(Sequence No. 428)
This sequence releases the setting of work automatic detection function.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not turned ON.
Automatic Detection List Request (3000-series, High-speed
Type) (Sequence No. 429)
This sequence requests the settings of work automatic detection function.
Send Data Word Allocation (2nd Operand of PMCR)
None.