Omron CQM1H-SCB41 Computer Hardware User Manual


 
367
Appendix M
V600/V620 ID Controller Protocol
The V600/V620 ID Controller Protocol is used to make various settings or control remotely the ID Controller Con-
nected to the Serial Communications Board via RS-232C or RS-422A cable.
Protocol Configuration
The configuration of the V600/V620 ID Controller Protocol is shown below.
Sequence Communications Function
Ladder interface
No. sequence name
Send word
allocation
Receive word
allocation
500 Read (ASCII/1) Used when the number of Heads to be read
from the Carrier is 1.
Yes Yes
501 Read (ASCII/2) Used when the number of Heads to be read
from the Carrier is 2.
Yes Yes
502 Read (ASCII/4) Used when the maximum number of Heads to
be read from the Carrier is 4.
Yes Yes
503 Read (ASCII/8) Used when the maximum number of Heads to
be read from the Carrier is 8.
Yes Yes
504 Read (Hexadeci-
mal/1)
Used when the number of Heads to be read
from the Carrier is 1.
Yes Yes
505 Read (Hexadeci-
mal/2)
Used when the number of Heads to be read
from the Carrier is 2.
Yes Yes
506 Read (Hexadeci-
mal/4)
Used when the maximum number of Heads to
be read from the Carrier is 4.
Yes Yes
507 Read (Hexadeci-
mal/8)
Used when the maximum number of Heads to
be read from the Carrier is 8.
Yes Yes
508 Auto-read (ASCII/1) Used when the number of Heads to be read
from the Carrier is 1.
Yes Yes
509 Auto-read (Hexade-
cimal/1)
Used when the number of Heads to be read
from the Carrier is 1.
Yes Yes
510 Polling Auto-read
(ASCII)
Used when the number of Heads to be read
from the Carrier is from 1 to 8.
Yes No
511 Polling Auto-read
Subcommand
(ASCII/2)
Used when the number of Heads to be read
from the Carrier is 2.
Yes Yes
512 Polling Auto-read
Subcommand
(ASCII/4)
Used when the maximum number of Heads to
be read from the Carrier is 4.
Yes Yes
513 Polling Auto-read
Subcommand
(ASCII/8)
Used when the maximum number of Heads to
be read from the Carrier is 8.
Yes Yes
514 Polling Auto-read
(Hexadecimal)
Used when the number of Heads to be read
from the Carrier is from 1 to 8.
Yes No
515 Polling Auto-read
Subcommand (Hexa-
decimal/2)
Used when the number of Heads to be read
from the Carrier is 2.
Yes Yes
516 Polling Auto-read
Subcommand (Hexa-
decimal/4)
Used when the maximum number of Heads to
be read from the Carrier is 4.
Yes Yes
517 Polling Auto-read
Subcommand (Hexa-
decimal/8)
Used when the maximum number of Heads to
be read from the Carrier is 8.
Yes Yes
518 Write (ASCII/1) Used when the number of Heads to be written
to the Carrier is 1.