Appendix JV500/V520 Bar Code Reader Protocol
313
Preset Data Set (V500) (Sequence No. 357)
This sequence sets preset data.
Send Data Word Allocation (2nd Operand of PMCR)
(Undefined)
Number of units
+0
+1
+2
+3
+4
+5
+18
+19
+(18N+2)
+(18N+3)
+(18N+4)
+(18N+5)
+(18N+18)
+(18N+19)
Number of send data wordsFirst word of
send data
~ ~
Preset data
(Undefined)
Number of presets
Preset data
(Undefined)
Preset data No.
(Undefined)
Preset data No.
Preset data
Preset data
Preset data
~ ~
(Undefined)
Number of units
Preset data
~ ~
Preset data
Preset data
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
18N+2 (N is number of presets 1 to 5)
+1 Number of presets
(1 digit BCD)
1 to 5
+2 Preset data No.
(1 digit BCD)
1 to 5
+3 Data length
(2 digits BCD)
01 to 32
+4 to
+19
Preset data (ASCII) Combination of the following ASCII characters and up
to 32 characters maximum:
30 (’0’) to 39 (’9’)
41 (’A’) to 5A (’Z’), 3F (’?’)
The area that is not used is undefined
+20 to
+91
Store repeatedly the contents of words with offsets +2
to +19 the same number of times as the number of
presets (N)
Receive Data Word Allocation (3rd Operand of PMCR)
None.
BCR Connection Confirmation (V500) (Sequence No. 358)
This sequence confirms whether the Bar Code Reader is connected correctly or not.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.