Appendix K3Z4L Laser Micrometer Protocol
346
General-purpose Command 1 (4000-series) (Sequence No. 444)
This general-purpose command is used to send data with a specified data length, and receive back only OK. The
terminator (CR) is automatically attached to the send data.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Number of send data words+0
+1
+2
+3
+128
+129
Send data
Send data byte length
Send data
Send data
D
D
Send data CR
Offset Contents (data format) Data
+0 Number of send data words
(4 digits BCD)
0003 to 0129
+1 Send data byte length (4 digits BCD) 0001 to 0255
The number of bytes of send data
excluding the terminator (CR)
+2 to
+129
Send data (ASCII) Send data up to 255 bytes maximum
Specify in ASCII.
Receive Data Word Allocation (3rd Operand of PMCR)
None.