3Com 3CRWX440095A Webcam User Manual


 
display system 43
===============================================================================
Fan status: fan1 OK fan2 OK fan3 OK
Temperature: temp1 ok temp2 ok temp3 ok
PSU Status: Lower Power Supply DC ok AC ok Upper Power Supply missing
Memory: 97.04/744.03 (13%)
Total Power Over Ethernet : 29.000
===============================================================================
Table 7 describes the fields of display system output.
Table 7 display system output
Field Description
Product Name Switch model number.
System Name System name (factory default, or optionally configured
with set system name).
System Countrycode Country-specific 802.11 code required for MAP operation
(configured with set system countrycode).
System Location Record of the WX switch’s physical location (optionally
configured with set system location).
System Contact Contact information about the system administrator or
another person to contact about the system (optionally
configured with set system contact).
System IP Common interface, source, and default IP address for the
device, in dotted decimal notation (configured with set
system ip-address).
System MAC WX switch’s media access control (MAC) machine address
set at the factory, in 6-byte hexadecimal format.
License License level installed on the WX switch (if applicable).
Boot Time Date and time of the last system reboot.
Uptime Number of days, hours, minutes, and seconds that the WX
has been operating since its last restart.
Fan status Operating status of the WX switch’s three cooling fans:
OK — Fan is operating.
Failed — Fan is not operating. MSS sends an alert to
the system log every 5 minutes until this condition is
corrected.
Fan 1 is located nearest the front of the chassis, and fan 3
is located nearest the back.