44 CHAPTER 3: SYSTEM SERVICE COMMANDS
See Also
clear system on page 39
set system contact on page 51
set system countrycode on page 51
set system ip-address on page 53
set system location on page 54
set system name on page 55
Temperature Status of temperature sensors at three locations in the WX
switch:
ok — Temperature is within the acceptable range of
0° C to 50° C (32° F to 122° F).
Alarm — Temperature is above or below the
acceptable range. MSS sends an alert to the system log
every 5 minutes until this condition is corrected.
PSU Status Status of the lower and upper power supply units:
missing — Power supply is not installed or is
inoperable.
DC ok — Power supply is producing DC power.
DC output failure — Power supply is not producing
DC power. MSS sends an alert to the system log every
5 minutes until this condition is corrected.
AC ok — Power supply is receiving AC power.
AC not present — Power supply is not receiving AC
power.
Memory Current size (in megabytes) of nonvolatile memory
(NVRAM) and synchronous dynamic RAM (SDRAM), plus
the percentage of total memory space in use, in the
following format:
NVRAM size /SDRAM size (percent of total)
Total Power Over
Ethernet
Total power that the device is currently supplying to its
directly connected MAP access points, in watts.
Table 7 display system output (continued)
Field Description