NEAX2400 IPX Feature Programming Manual
Page 1028 NDA-24297, Issue 1
S-60 Synchronous Data Switching - CCIS
Programming (cont’d)
For Data Module
STEP 1: ASDT - Assign levels 1, 2, & 3 of a PA-4DTL as TEC = 16. Also assign an RSC and SFC.
STEP 2: ASFC - For TEC = 16 stations, assign an SFC that, at a minimum, SFI 11 = 0, DATA LINE
SECURITY.
STEP 3: ARSC - Construct a Route Restriction Class that allows access to the desired incoming and outgoing
routes. Those routes include PA-24DTA ACIS and CCIS routes.
STEP 4: ATNR - Allow tenant-to-tenant connection for Inter and Intra-tenant connections. Assign Tenant Re
subtraction Index (TRI) = 1.
STEP 5: ACFR - Allow all incoming Call Class Index (CCI) for Transfer Service Feature Index (TSFI) = 1.
STEP 6: ADA1 - The following attributes are assigned via the MAT using this command:
MEDIA: 2
CNTP: 0
TCP: 0
FCY: 0
PRI: 0
REST: 0
SRP: 0
STEP 7: ADA2 - It is possible to program Attribute Data 2, 3, and 10 from the MAT.
STEP 8: ARTD2 - The CCIS Tie Line voice/data route(s) over T-1 should be assigned as follows. For
SYNCHRONOUS DATA SWITCHING - CCIS CDN 45:A/D must be assigned as data “1” and CDN
30:PAD must be assigned as data “5”.
RT:1
2-ONSG :2 4-INSG :2 5-TF :3 6-TCL :4 7-L/T :1
8-RLP :2 13-AC :1 15-LSG :12 30-PAD :5 43-BT :1
45-A/D :1 49-TRKS :0/1* 50-DPLY :1
Note: *Optional