NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 199
Call Forwarding-Intercept / Announcement C-25
FCCS Programming (cont’d)
1 = Connection is held until the station is released. See the requirements of the application for
the announcement equipment. For Dead level applications, assign data “0”.
R: Sending RBT
0/1 = Yes/No
A: Answer Signal Sending (Answer from the incoming trunk)
0 = No/Yes Normally assign data “1”.
M: Multiple Connection
0/1 = Single Connection/Multiple Connection
LGRT: Logical Route Number
TK: Trunk Number *Not necessary for “M=1”
STEP 3: ARRCN - This data must be assigned to the NCN.
Release the restriction between the terminating trunk and the announcement trunk.
STEP 4: ARSCN - This data must be assigned to the NCN.
Release the restriction between the announcement trunk and the station.
Note: The current command data shown is set to all nodes using the service: ASTD, ARTD, ATRK, MBTK