NEAX2400 IPX Feature Programming Manual
Page 692 NDA-24297, Issue 1
S-15 Serial Call
Programming
STEP 1: ASYD - System Data 1, Index 186, Bit 4. Serial Call Loop Release 0/1: OUT/In Service When data
“1” is assigned, CCSA calls will not ring the ATT. In this case, change ARTD CDN 6:TCL from
CCSA to DDD Line, TIE Line, etc.
System Data 2, Index 7, Bit 2. Is SERIAL CALL to be enabled on a per-tenant basis? 0/1: No/Yes.
System Data 1, Index 43, Bit 4. Is Attendant able to reenter loop of serial call? 0/1: No/Yes.
FCCS Programming
No unique programming is required for the FCCS network.