NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 89
Brokerage - Hotline B-6
Service Conditions (cont’d)
• the destination station is off-hook.
• the destination station is already engaged in a three-party call.
c.) the destination is the Attendant or is connected to an outside party.
16. When EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] is used with this feature, it is not activated under any
of the following conditions:
• when utilizing EXECUTIVE RIGHT-OF-WAY [E-1, E-1D] service using switch hook flash and
access code.
• when all three-party conference trunks are busy.
• when the destination is not in the two-party connection (an incoming call is in the middle of terminating
to the destination or the destination places a call on hold or the destination is in off-hook status or the
three-party connection including the destination has already been established).
• when the destination is connected with the Attendant Console or the C.O. trunk.
17. This feature can be activated via FCCS.
18. Only the station assigned a telephone number is available for the station assignment when activating this
feature via FCCS.
19. The station, the Attendant Console/Desk Console (operator call), and the trunk can be a destination for
Hotline.
20. When Call Forwarding - All Calls/Busy Line/Don’t Answer service has been set to the called station, these
features are available for the call to the station.
21. When a calling party encounters a busy station, the call may bridge into the connection, depending on the
data assigned by the ASYD command.
Programming
STEP 1: ASDT - Assign to a PA-16LC circuit the following data:
TN: Tenant Number
STN: Station Number
LENS: Line Equipment Number (6 digits) - Actual LENS for TEC 14, Virtual LENS for TEC 18
TEC: Telephone Class (1-31)
1: DP (10pps)
2: PB
3: DP/PB
12: D
term
13: Data terminal via D
term
14: HOTLINE
15: CAS Line
18: Virtual Circuit
RSC: Route Restriction class (0-15)
SFC: Service Feature Class (0-15)
STEP 2: AHLS - Assign the station numbers programmed above for the following parameters:
HOT TN: Hotline Tenant
STN: Hotline Station
TYPE: 1 = station
CON TN: Connecting Station’sTenant
CON STN: Connecting Station Number