NEC 2400 PX Webcam User Manual


  Open as PDF
of 1089
 
NEAX2400 IPX Feature Programming Manual
Page 348 NDA-24297, Issue 1
F-1 Flexible Numbering of Stations
F-1 Flexible Numbering of Stations
General Description
This feature provides the ability to assign telephone numbers of the voice station and data station to any
corresponding instrument location, depending solely upon numbering plan limitations.
Operating Procedure
Refer to the NEAX2400 IPX Office Data Specification.
Service Conditions
1. Careful consideration should be given to any numbering assignment, especially in larger systems, to avoid
the unnecessary loss of access codes or duplication of telephone numbers. There is no limit to the number
of groups that can be assigned per system.
2. Where TENANT SERVICE [T-12] is provided, telephone numbers may not be duplicated between
tenants. A combination of one, two, three, four and five-digit numbering may be used.
Example: a. 3 1
b.321
c.3221
Example a., b., c., can be assigned as 3 different stations.
3. BUSY LAMP FIELD - FLEXIBLE [B-2] service can be provided only when the defining telephone
number digits exceed two.
4. The FCCS network allows the user to use a telephone number in addition to the existing station numbers.
FCCS service features are activated when a telephone number is dialed. A telephone number, which can
be assigned on a station basis, is a unique number on the FCCS network.
Note: A maximum of 16 digits can be used as a telephone number. When OAI/ACD/Hospitality features are used,
a maximum of 5 digits can be used.
Interactions
Caution should be exercised when programming this feature. Large quantities of potential telephone numbers are
consumed. As programmed below, the system will be equipped with just one 2-digit station and one 3-digit station.
Programming
STEP 1: ASYD - System Data 1, Index 16. Enable 1 to 5-digit station numbering for the system. Assign 3FH.
System Data 1, Index 92, Bit 3. Must be assigned as data 1.
STEP 2: ANPD - Reserve an access code for station numbering. For the NND parameter, assign the NND to the
smallest quantity of digits planned for station numbering that will use the busy lamp field. Only the