NEAX2400 IPX Feature Programming Manual
Page 260 NDA-24297, Issue 1
C-157 Calling Party Number - Name Assignment and Display
Service Conditions (cont’d)
18. The trunk mentioned below is available as for analog COT:
19. When this feature is activated via FCCS, the same data should be set to all nodes.
Programming
STEP 1: ASYD - System Data 1, Index 241, b6: Assign the data when the length of Caller ID exceeds the limit:
0/1 = Only the former/latter part of data appears on the LCD.
Index 390,
b0: Assign the prior data to display
0/1: The Assigned Name/The Calling Number
b1: Assign the information displayed on the top line of the LCD
0/1: 0=Caller ID data
1=Call Type, Sub-address
b2: Enable to display Caller ID information on the D
term
to which the called line is assigned as a
sub line.
0/1: Out/In service
STEP 2: ACID - Assign the desired name against the calling number.
TYPE 3: Calling Party Number - Name Assignment and Display
CID: Caller ID Number
SRV3:1 Calling Party Number - Name Assignment and Display
NAME: 24 digits maximum
STEP 3: AKYD - Assign the Call ID display change key to a feature key. FKY = 113
STEP 4: ADSL - Assign the Call ID display change key to a soft key.
SN = 0, 3
FKY = 113
FCCS Programming
No unique programming is required for the FCCS network.
CIRCUIT CARD NAME REMARKS
PA-8COTBJ