NEAX2400 IPX Feature Programming Manual
Page 906 NDA-24297, Issue 1
D-86 Data Hotline - CCIS
Interactions (cont’d)
4. TOLL DIVERSION/TOLL DENIAL [T-6] and TOLL RESTRICTION-3/6 DIGIT [T-7] will not interact
with this feature if a station is allowed access to an ADC via Service Feature Class.
5. This feature designates the use of a SPEED CALLING-SYSTEM [S-3] number when the DATA key is
activated.
6. UNIVERSAL SENDER [U-3] must also be provided.
Programming
STEP 1: ASDT - Assign the Data Terminal Number.
STEP 2: AKYD -AssigntheD
term
feature keys.
FKY: Feature Key Number
29: Data (DATA)
30: Display/Auto (DSPY/AUTO)
31: Data Transfer (DTX)
STEP 3: ATNR - Assign Connection Restriction for tenant.
RES:
0: Restricted
1: Allowed
STEP 4: AEFR - Assign Connection Restriction for RSC.
RSC1: Calling Restriction Class (0-15)
RSC2: Calling Restriction Class (0-15)
RES: Restriction Data
0: Restricted
1: Allowed
STEP 5: ADA1 -AssignDTEAttributeData1.
CDN: Counter Display Number = 1
MEDIA:1-15
2: Data
CDN: Counter Display Number = 2
MEDIA:0-15
0: 2400 Protocol
1: X. 20
2: X. 21
3: V. 24 200 Series
4: X. 20 bis
5: X. 21 bis
6-15: Not used
STEP 6: ASPD - Assign the Speed Calling:
ADC: Abbreviated Digit Code (2 or 3 digits)
00-99: 100 Speed-Calling Numbers
000-999: 1000 Speed-Calling Numbers
CD: Telephone number (maximum 24 digits) corresponding to the ADC.
STEP 7: AHLS - Assign speed numbering for TN No. of Hotline Terminal, station number.
HOT TN: Hotline Tenant Number