NEAX2400 IPX Feature Programming Manual
Page 584 NDA-24297, Issue 1
P-7 Peg Count
P-7 Peg Count
General Description
This service feature permits traffic studies and traffic analysis information to be accessed from the
MAINTENANCE ADMINISTRATION TERMINAL (MAT) [M-18] and printed out.
Operating Procedure
Refer to the NEAX2400 IPX System Operations and Maintenance Manual.
Service Conditions
1. This feature can be used for the FCCS network. For details, refer to the NEAX2400 IPX Operations and
Maintenance Manual.
2. All information required for this feature is registered at the MAT.
3. The following information is available:
STATION PEG COUNT:
Number of call originations attempted
Number of station-to-station or station-to-Attendant calls attempted
Number of station-to-trunk calls attempted
Number of call originations abandoned
Number of station-to-station calls terminated
Number of trunk-to-station calls terminated
Number of total calls terminated to station
Number of calls unanswered within a predetermined time
Number of calls answered
Number of calls unanswered
Number of calls hearing busy tone and forwarded to the ATTENDANT CONSOLE [A-3]
ATTENDANT PEG COUNT:
Number of incoming calls per INCOMING CALL IDENTIFICATION [I-2] lamp
Number of calls answered per INCOMING CALL IDENTIFICATION [I-2] busy
ROUTE PEG COUNT:
Number of times trunk route seizure attempted
Number of times all trunks busy reached
Number of times trunk seized
Number of calls terminated to trunk route
Number of incoming calls that seized register
Number of incoming calls directed to ATTENDANT CONSOLE [A-3]
Number of incoming calls directed to station
Number of incoming calls directed to tandem connection
Number of incoming calls abandoned
4. The above information may be registered and cancelled as required.
5. The measurement information printout cycle can be any period of time ranging from 30 minutes to 120
minutes (in 10-minute increments), as required.