NEAX2400 IPX Feature Programming Manual
Page 584 NDA-24297, Issue 1
P-7 Peg Count
P-7 Peg Count
General Description
This service feature permits traffic studies and traffic analysis information to be accessed from the
MAINTENANCE ADMINISTRATION TERMINAL (MAT) [M-18] and printed out.
Operating Procedure
Refer to the NEAX2400 IPX System Operations and Maintenance Manual.
Service Conditions
1. This feature can be used for the FCCS network. For details, refer to the NEAX2400 IPX Operations and
Maintenance Manual.
2. All information required for this feature is registered at the MAT.
3. The following information is available:
STATION PEG COUNT:
• Number of call originations attempted
• Number of station-to-station or station-to-Attendant calls attempted
• Number of station-to-trunk calls attempted
• Number of call originations abandoned
• Number of station-to-station calls terminated
• Number of trunk-to-station calls terminated
• Number of total calls terminated to station
• Number of calls unanswered within a predetermined time
• Number of calls answered
• Number of calls unanswered
• Number of calls hearing busy tone and forwarded to the ATTENDANT CONSOLE [A-3]
ATTENDANT PEG COUNT:
• Number of incoming calls per INCOMING CALL IDENTIFICATION [I-2] lamp
• Number of calls answered per INCOMING CALL IDENTIFICATION [I-2] busy
ROUTE PEG COUNT:
• Number of times trunk route seizure attempted
• Number of times all trunks busy reached
• Number of times trunk seized
• Number of calls terminated to trunk route
• Number of incoming calls that seized register
• Number of incoming calls directed to ATTENDANT CONSOLE [A-3]
• Number of incoming calls directed to station
• Number of incoming calls directed to tandem connection
• Number of incoming calls abandoned
4. The above information may be registered and cancelled as required.
5. The measurement information printout cycle can be any period of time ranging from 30 minutes to 120
minutes (in 10-minute increments), as required.