System Management: Vendor Commands
10007175-02 KAT4000 User’s Manual
9-13
commands to provide a response (if necessary). The event notification character is sent in a
synchronous manner, and does not appear in the contents of SIPL messages sent to the
payload.
Table 9-7: Get Status Command
Type: Byte: Data Field:
Request Data 1:3 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data 1 Completion Code
2:4 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data
(continued)
5 Bit [7] Graceful Reboot Request
If set to 1, indicates that the payload is requested to initiate the
graceful reboot sequence
Bit [6] Diagnostic Interrupt Request
If set to 1, indicates that a payload diagnostic interrupt request
has arrived
Bit [5] Shutdown Alert
If set to 1, indicates that the payload is going to be shutdown
Bit [4] Reset Alert
If set to 1, indicates that the payload is going to be reset
Bit [3] Sensor Alert
If set to 1, indicates that at least one of the IPMC sensors
detects threshold crossing
Bits [2:1] Mode
The current IPMC modes are defined as:
0Normal
1Standalone
2 Manual Standalone
Bit [0] Control
If set to 0, the IPMC control over the payload is disabled
6 Bits [4:7] Metallic Bus 2 Events
These bits indicate pending Metallic Bus 2 requests arrived from
the shelf manager:
0 Metallic Bus 2 Query
1 Metallic Bus 2 Release
2 Metallic Bus 2 Force
3 Metallic Bus 2 Free
Bits [0:3] Metallic Bus 1 Events
These bits indicate pending Metallic Bus 1 requests arrived from
the shelf manager:
0 Metallic Bus 1 Query
1 Metallic Bus 1 Release
2 Metallic Bus 1 Force
3 Metallic Bus 1 Free