Emerson KAT4000 Network Hardware User Manual


 
System Management: Entities and Entity Associations
10007175-02 KAT4000 User’s Manual
9-39
ENTITIES AND ENTITY ASSOCIATIONS
The AdvancedTCA specification (see PICMG Engineering Change Notice 3.0 listed in Tab le 1 -
3
) uses Entity IDs and Instances to describe physical components associated with FRUs.
Device-relative Entities are unique to a specific IPMC and are referenced as follows in the
specification:
r(<ipmb>,<lun>,<Entity ID>,<Entity Instance – 60>)
Using this terminology, a KAT4000 (CPU and no PCIe configuration) installed in Logical Slot
1 (IPMB 82) has the description in
Fig.9-4.
6 Local Control Color
Bits [7:4] Reserved, set to 0
Bits [3:0]
0h Reserved
1h Blue
2h Red
3h Green
4h Amber
5h Orange
6h White
7h-Fh Reserved
7 Override State LED Functionis required if either override state or
Lamp Test is in effect.
00h LED override state is off
01h-FAh LED override state is blinking Off duration is
specified by this byte, on duration specified by
byte 8 (in tens of milliseconds)
FBh-FEh Reserved
FFh LED override state is on
8 Override State On Durationis required if either override state or
Lamp Test is in effect (in tens of milliseconds).
9 Override State Color
Bits [7:4] Reserved, set to 0
Bits [3:0]
0h Reserved
1h Blue
2h Red
3h Green
4h Amber
5h Orange
6h White
7h-Fh Reserved
10 Lamp Test Durationis optional if Lamp Test is not in effect
(hundreds of milliseconds).
Type: Byte: Data Field: (continued)