System Management: Vendor Commands
10007175-02 KAT4000 User’s Manual
9-23
Table 9-22: Bused Resource Status Command
Graceful Reset Command
The IPMC supports the Graceful Reboot option of the FRU Control command. On receiving
such a command, the IPMC sets the Graceful Reboot Request bit of the IPMC status, sends a
status update notification to the payload, and waits for the Graceful Reset command from
the payload. If the IPMC receives such a command before the payload communication
time-out time, it sends the 0x00 completion code (Success) to the shelf manager. Other-
wise the 0xCC completion code is sent.
Type: Byte: Data Field:
Request Data 1:3 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4 Command Types for Shelf Manager to Board
0 Query if board has control of the bus
(0=In control, 1= No control)
1 Release request a board to release control of the bus
(0=Ack, 1=Refused, 2=No control)
2 Force board to release control of bus immediately
(0=Ack, 1=No control)
3 Bus Free informs board that the bus is available
(0=Accept, 1=Not needed)
Command Types for Board to Shelf Manager
0 Request to seize control of the bus
(0=Grant, 1=Busy, 2=Defer, 3=Deny)
1 Relinquish control of the bus, Shelf Manager can reassign
control of bus (0=Ack, 1=Error)
2 Notify Shelf Manager that control of the bussed resource has
been transferred to this board from another authorized board
(0=Ack, 1=Error, 2=Deny)
5Bused Resource ID
0 Metallic Test Bus pair #1
1 Metallic Test Bus pair #2
2 Synch clock group 1 (CLK1A and CLK1B pairs)
3 Synch clock group 2 (CLK2A and CLK2B pairs)
4 Synch clock group 3 (CLK3A and CLK3B pairs)
6 Status
0 Ack; Shelf Manager acknowledges that board has control
1 Error; same as Ack, but Shelf Manager believes board should
not have been given control of the resource (optional)
2 Deny; Shelf Manager denies control of resource by the board
Response Data 1 Completion Code
2:4 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)