Emerson KAT4000 Network Hardware User Manual


 
Appendix B: Sensor Data Records
10007175-02 KAT4000 User’s Manual
B-19
Table B-12: Inflow Temp SDR Description
Positive-Going Threshold Hyst
Value
03
Negative-Going Threshold Hyst
Value
03
OEM 00
ID String Type / Length Code c8
KAT4000 Records: Value: Parameter: Status:
Record ID 000a
SDR Version 51
Record Type 01 Full Sensor Record
Record Length 36
Sensor Owner ID 00
Sensor Owner LUN 00
Sensor Number 00
Entity ID a0
Entity Instance 60
Sensor Initialization 7f Init Scanning
Init Sensor Type
Init Hysteresis
Init Thresholds
Init Events
Sensor Scanning enabled
Event Generation enabled
Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 01 Temperature
Event/Reading Type Code 01 Threshold
KAT4000 Records: Value: Parameter: Status: (continued)