Appendix B: Sensor Data Records
KAT4000 User’s Manual 10007175-02
B-40
Table B-24: B3 +12V Volt SDR Description
ID String Type / Length Code cc — —
KAT4000 Records: Value: Parameter: Status:
Record ID 0016 — —
SDR Version 51 — —
Record Type 01 Full Sensor Record —
Record Length 37 — —
Sensor Owner ID 00 — —
Sensor Owner LUN 00 — —
Sensor Number 00 — —
Entity ID c1 AMC Module —
Entity Instance 67 — —
Sensor Initialization 5d Init Scanning —
Init Sensor Type —
Init Hysteresis —
Init Thresholds —
Sensor Scanning enabled
Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 02 Voltage —
Event/Reading Type Code 01 Threshold —
Assertion Event Mask 0800 Upper Non-Recoverable Going High supported
Deassertion Event Mask 4800 Lower Non-Recoverable Threshold comparison returned
Upper Non-Recoverable Going High supported
Discrete Reading Mask 3838 Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
Sensor Units 1 00 Analog Data Format unsigned
Rate Unit none
Modifier Unit none
Percentage no
Sensor Units 2 - Base Unit 04 Volts —