Appendix B: Sensor Data Records
10007175-02 KAT4000 User’s Manual
B-55
Sensor Owner ID 00 — —
Sensor Owner LUN 00 — —
Sensor Number 00 — —
Entity ID 0a — —
Entity Instance 60 — —
Sensor Initialization 7f Init Scanning —
Init Sensor Type —
Init Hysteresis —
Init Thresholds —
Init Events —
Sensor Scanning enabled
Event Generation enabled
Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 02 Voltage —
Event/Reading Type Code 01 Threshold —
Assertion Event Mask 4801 Lower Non-Recoverable Threshold comparison returned
Upper Non-Recoverable Going High supported
Lower Non-Critical Going Low supported
Deassertion Event Mask 4801 Lower Non-Recoverable Threshold comparison returned
Upper Non-Recoverable Going High supported
Lower Non-Critical Going Low supported
Discrete Reading Mask 3f3f Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Lower Non-Recoverable Threshold settable
Lower Critical Threshold settable
Lower Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
Lower Non-Recoverable Threshold readable
Lower Critical Threshold readable
Lower Non-Critical Threshold readable
KAT4000 Records: Value: Parameter: Status: (continued)