Emerson KAT4000 Network Hardware User Manual


 
Appendix B: Sensor Data Records
10007175-02 KAT4000 User’s Manual
B-13
Table B-9: +1.2 Volt SDR Description
Lower Non-Recoverable
Threshold
93
Lower Critical Threshold 00
Lower Non-Critical Threshold 00
Positive-Going Threshold Hyst
Value
03
Negative-Going
Threshold Hyst Value
03
OEM 00
ID String Type / Length Code c5
KAT4000 Records: Value: Parameter: Status:
Record ID 0007
SDR Version 51
Record Type 01 Full Sensor Record
Record Length 30
Sensor Owner ID 00
Sensor Owner LUN 00
Sensor Number 00
Entity ID 14 Power Module / DC-to-DC Converter
Entity Instance 60
Sensor Initialization 7f Init Scanning
Init Sensor Type
Init Hysteresis
Init Thresholds
Init Events
Sensor Scanning enabled
Event Generation enabled
Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 02 Voltage
Event/Reading Type Code 01 Threshold
Assertion Event Mask 4000 Lower Non-Recoverable Threshold comparison returned
Deassertion Event Mask 4000 Lower Non-Recoverable Threshold comparison returned
KAT4000 Records: Value: Parameter: Status: (continued)