Table 12-4: Zone 3 Connector, J30 Pin Assignments
Table 12-5: Zone 3 Connector, J31 Pin Assignments
Row: A B C D
1 FP_CONN_TX FP_CONN_RX B3_RTIP4 B3_RRING4
2 B3_TTIP6 B3_TRING6 B3_RTIP6 B3_RRING6
3 B3_TTIP8 B3_TRING8 B3_RTIP8 B3_RRING8
4 RTM_ENET_TX+ RTM_ENET_TX-
no connect no connect
5 RTM_ENET_RX+ RTM_ENET_RX- B4_RTIP2 B4_RRING2
6 HOST_CONN_TX HOST_CONN_RX RTM_ID1 PB_RST*
7 B4_TTIP3 B4_TRING3 IPMC_RST_PB* RTM_ID0
8 B4_TTIP4 B4_TRING4 RTM_ID3
no connect
9 B4_TTIP5 B4_TRING5 B4_RTIP5 B4_RRING5
10 B4_TTIP7 B4_TRING7 B4_RTIP7 B4_RRING7
Row: E F G H
1 B3_TTIP5 B3_TRING5 B3_RTIP5 B3_RRING5
2 B3_TTIP7 B3_TRING7 B3_RTIP7 B3_RRING7
3 GIG6_TX+ GIG6_TX-
no connect no connect
4
no connect no connect B4_TTIP2 B4_TRING2
5 B4_TTIP1 B4_TRING1 B4_RTIP1 B4_RRING1
6 GIG6_RX+ GIG6_RX- RTM_PS1_CONN* AMC_PP_EN*
7 B4_RTIP3 B4_RRING3 RTM_ID2
no connect
8
no connect no connect B4_RTIP4 B4_RRING4
9 B4_TTIP6 B4_TRING6 B4_RTIP6 B4_RRING6
10 B4_TTIP8 B4_TRING8 B4_RTIP8 B4_RRING8
Row: A B C D
1 no connect no connect RTM_GPIO7 RTM_GPIO6
2 B2_TTIP3 B2_TRING3 RTM_GPIO5 RTM_GPIO4
3 B2_TTIP4 B2_TRING4
no connect no connect
4 B2_TTIP5 B2_TRING5 B2_RTIP5 B2_RRING5
5 B2_TTIP7 B2_TRING7 B2_RTIP7 B2_RRING7
6 RTM_RX0+ RTM_RX0-
no connect no connect
7 RTM_RX1+ RTM_RX1- B3_TTIP2 B3_TRING2
8 B3_TTIP1 B3_TRING1 B3_RTIP1 B3_RRING1
9
no connect no connect RTM_RX2+ RTM_RX2-
10 B3_RTIP3 B3_RRING3 RTM_RX3+ RTM_RX3-