Appendix B: Sensor Data Records
KAT4000 User’s Manual 10007175-02
B-46
Discrete Reading Mask 3f3f Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Lower Non-Recoverable Threshold settable
Lower Critical Threshold settable
Lower Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
Lower Non-Recoverable Threshold readable
Lower Critical Threshold readable
Lower Non-Critical Threshold readable
Sensor Units 1 00 Analog Data Format unsigned
Rate Unit none
Modifier Unit none
Percentage no
Sensor Units 2 - Base Unit 04 Volts —
Sensor Units 3 - Modifier Unit 00 Unspecified —
Linearization 00 — —
M23— —
M, Tolerance 40 — —
B00— —
B, Accuracy 00 — —
Accuracy, Accuracy Exp 00 — —
R exp, B Exp d0 — —
Analog Characteristic Flags 07 — —
Nominal Reading a5 — —
Normal Maximum f8 — —
Normal Minimum 7c — —
Sensor Maximum Reading ff — —
Sensor Minimum Reading 00 — —
Upper Non-Recoverable
Threshold
f8 — —
Upper Critical Threshold 00 — —
Upper Non-Critical Threshold 00 — —
Lower Non-Recoverable
Threshold
7c — —
Lower Critical Threshold 00 — —
Lower Non-Critical Threshold 00 — —
KAT4000 Records: Value: Parameter: Status: (continued)