Table B-28: -48V Current SDR Description
Positive-Going Threshold Hyst
Value
02
Negative-Going Threshold Hyst
Value
02
OEM 00
ID String Type / Length Code c9
KAT4000 Records: Value: Parameter: Status:
Record ID 001a
SDR Version 51
Record Type 01 Full Sensor Record
Record Length 34
Sensor Owner ID 00
Sensor Owner LUN 00
Sensor Number 00
Entity ID 0a
Entity Instance 60
Sensor Initialization 7f Init Scanning
Init Sensor Type
Init Hysteresis
Init Thresholds
Init Events
Sensor Scanning enabled
Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 03 Current
Event/Reading Type Code 01 Threshold
Assertion Event Mask 0800 Upper Non-Recoverable Going High supported
Deassertion Event Mask 4800 Lower Non-Recoverable Threshold comparison returned
Upper Non-Recoverable Going High supported
Discrete Reading Mask 3838 Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
KAT4000 Records: Value: Parameter: Status: (continued)