Appendix B: Sensor Data Records
10007175-02 KAT4000 User’s Manual
B-43
Table B-26: B4 +12V Volt SDR Description
Sensor Minimum Reading 00 — —
Upper Non-Recoverable
Threshold
ff — —
Upper Critical Threshold 00 — —
Upper Non-Critical Threshold 00 — —
Lower Non-Recoverable
Threshold
00 — —
Lower Critical Threshold 00 — —
Lower Non-Critical Threshold 00 — —
Positive-Going Threshold Hyst
Value
03 — —
Negative-Going Threshold Hyst
Value
00 — —
OEM 00 — —
ID String Type / Length Code cc — —
KAT4000 Records: Value: Parameter: Status:
Record ID 0018 — —
SDR Version 51 — —
Record Type 01 Full Sensor Record —
Record Length 37 — —
Sensor Owner ID 00 — —
Sensor Owner LUN 00 — —
Sensor Number 00 — —
Entity ID c1 AMC Module —
Entity Instance 68 — —
Sensor Initialization 5d Init Scanning —
Init Sensor Type —
Init Hysteresis —
Init Thresholds —
Sensor Scanning enabled
Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 02 Voltage —
Event/Reading Type Code 01 Threshold —
Assertion Event Mask 0800 Upper Non-Recoverable Going High supported
KAT4000 Records: Value: Parameter: Status: (continued)