Emerson KAT4000 Network Hardware User Manual


 
Appendix B: Sensor Data Records
KAT4000 User’s Manual 10007175-02
B-24
Table B-14: Version Change SDR Description
Positive-Going Threshold Hyst
Value
02
Negative-Going Threshold Hyst
Value
02
OEM 00
ID String Type / Length Code cc
KAT4000 Records: Value: Parameter: Status:
Record ID 000c
SDR Version 51
Record Type 01 Full Sensor Record
Record Length 39
Sensor Owner ID 00
Sensor Owner LUN 00
Sensor Number 00
Entity ID a0
Entity Instance 60
Sensor Initialization 67 Init Scanning
Init Sensor Type
Init Events
Sensor Scanning enabled
Event Generation enabled
Sensor Capabilities 41 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis no hysteresis
Sensor Threshold Access no threshold
Event Message Control global disable only
Sensor Type 2b
Event/Reading Type Code 6f Sensor Specific
Assertion Event Mask 00ff
Deassertion Event Mask 0000
Discrete Reading Mask 00ff
Sensor Units 1 00 Analog Data Format unsigned
Rate Unit none
Modifier Unit none
Percentage no
Sensor Units 2 - Base Unit 00 Unspecified
Sensor Units 3 - Modifier Unit 00 Unspecified
Linearization 00
KAT4000 Records: Value: Parameter: Status: (continued)