Appendix B: Sensor Data Records
KAT4000 User’s Manual 10007175-02
B-14
Discrete Reading Mask 3f3f Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Lower Non-Recoverable Threshold settable
Lower Critical Threshold settable
Lower Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
Lower Non-Recoverable Threshold readable
Lower Critical Threshold readable
Lower Non-Critical Threshold readable
Sensor Units 1 00 Analog Data Format unsigned
Rate Unit none
Modifier Unit none
Percentage no
Sensor Units 2 - Base Unit 04 Volts
Sensor Units 3 - Modifier Unit 00 Unspecified
Linearization 00
M62
M, Tolerance 00
B00
B, Accuracy 00
Accuracy, Accuracy Exp 00
R exp, B Exp c0
Analog Characteristic Flags 07
Nominal Reading 7b
Normal Maximum 87
Normal Minimum 6f
Sensor Maximum
Reading
ff
Sensor Minimum Reading 00
Upper Non-Recoverable
Threshold
93
Upper Critical Threshold 00
Upper Non-Critical Threshold 00
Lower Non-Recoverable
Threshold
62
Lower Critical Threshold 00
Lower Non-Critical Threshold 00
KAT4000 Records: Value: Parameter: Status: (continued)