Emerson KAT4000 Network Hardware User Manual


 
Appendix B: Sensor Data Records
10007175-02 KAT4000 User’s Manual
B-23
Discrete Reading Mask 3f3f Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Lower Non-Recoverable Threshold settable
Lower Critical Threshold settable
Lower Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
Lower Non-Recoverable Threshold readable
Lower Critical Threshold readable
Lower Non-Critical Threshold readable
Sensor Units 1 80 Analog Data Format twos complement
Rate Unit none
Modifier Unit none
Percentage no
Sensor Units 2 - Base Unit 01 Degrees C
Sensor Units 3 - Modifier Unit 00 Unspecified
Linearization 00
M64
M, Tolerance 00
B00
B, Accuracy 00
Accuracy, Accuracy Exp 00
R exp, B Exp e0
Analog Characteristic Flags 07
Nominal Reading 20
Normal Maximum 37
Normal Minimum 00
Sensor Maximum Reading 7f
Sensor Minimum Reading 80
Upper Non-Recoverable
Threshold
55
Upper Critical Threshold 4b
Upper Non-Critical Threshold 41
Lower Non-Recoverable
Threshold
f1
Lower Critical Threshold f6
Lower Non-Critical Threshold fb
KAT4000 Records: Value: Parameter: Status: (continued)