Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 02 Voltage —
Event/Reading Type Code 01 Threshold —
Assertion Event Mask 4801 Lower Non-Recoverable Threshold comparison returned
Upper Non-Recoverable Going High supported
Lower Non-Critical Going Low supported
Deassertion Event Mask 4801 Lower Non-Recoverable Threshold comparison returned
Upper Non-Recoverable Going High supported
Lower Non-Critical Going Low supported
Discrete Reading Mask 3f3f Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Lower Non-Recoverable Threshold settable
Lower Critical Threshold settable
Lower Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
Lower Non-Recoverable Threshold readable
Lower Critical Threshold readable
Lower Non-Critical Threshold readable
Sensor Units 1 00 Analog Data Format unsigned
Rate Unit none
Modifier Unit none
Percentage no
Sensor Units 2 - Base Unit 04 Volts —
Sensor Units 3 - Modifier Unit 00 Unspecified —
Linearization 00 — —
Ma2— —
M, Tolerance 00 — —
B00— —
B, Accuracy 00 — —
Accuracy, Accuracy Exp 00 — —
R exp, B Exp c0 — —
Analog Characteristic Flags 07 — —
Nominal Reading cc — —
KAT4000 Records: Value: Parameter: Status: (continued)