Emerson KAT4000 Network Hardware User Manual


 
Appendix B: Sensor Data Records
10007175-02 KAT4000 User’s Manual
B-57
Sensor Owner ID 00
Sensor Owner LUN 00
Sensor Number 00
Entity ID 0a
Entity Instance 60
Sensor Initialization 7f Init Scanning
Init Sensor Type
Init Hysteresis
Init Thresholds
Init Events
Sensor Scanning enabled
Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 03 Current
Event/Reading Type Code 01 Threshold
Assertion Event Mask 0800 Upper Non-Recoverable Going High supported
Deassertion Event Mask 4800 Lower Non-Recoverable Threshold comparison returned
Upper Non-Recoverable Going High supported
Discrete Reading Mask 3838 Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
Sensor Units 1 00 Analog Data Format unsigned
Rate Unit none
Modifier Unit none
Percentage no
Sensor Units 2 - Base Unit 05 Amps
Sensor Units 3 - Modifier Unit 00 Unspecified
Linearization 00
M6d
M, Tolerance 00
B00
B, Accuracy 00
Accuracy, Accuracy Exp 00
KAT4000 Records: Value: Parameter: Status: (continued)