Appendix B: Sensor Data Records
10007175-02 KAT4000 User’s Manual
B-57
Sensor Owner ID 00 — —
Sensor Owner LUN 00 — —
Sensor Number 00 — —
Entity ID 0a — —
Entity Instance 60 — —
Sensor Initialization 7f Init Scanning —
Init Sensor Type —
Init Hysteresis —
Init Thresholds —
Init Events —
Sensor Scanning enabled
Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 03 Current —
Event/Reading Type Code 01 Threshold —
Assertion Event Mask 0800 Upper Non-Recoverable Going High supported
Deassertion Event Mask 4800 Lower Non-Recoverable Threshold comparison returned
Upper Non-Recoverable Going High supported
Discrete Reading Mask 3838 Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
Sensor Units 1 00 Analog Data Format unsigned
Rate Unit none
Modifier Unit none
Percentage no
Sensor Units 2 - Base Unit 05 Amps —
Sensor Units 3 - Modifier Unit 00 Unspecified —
Linearization 00 — —
M6d— —
M, Tolerance 00 — —
B00— —
B, Accuracy 00 — —
Accuracy, Accuracy Exp 00 — —
KAT4000 Records: Value: Parameter: Status: (continued)