Common Switch Region: Ethernet Core Switch (optional)
KAT4000 User’s Manual 10007175-02
4-4
On-Board Path Device Settings
Caution: On-board device values are determined by Emerson. Do not change these values. Altering
on-board device values could cause system failure.
Note: Proprietary information regarding register function or effect is not available in this user’s manual. Please
contact the PHY or switch manufacturer directly for details.
Tab le 4 -1
lists the KAT4000 PHYs and their respective addresses.
Table 4-1: KAT4000 PHYs and Address Values
The Ethernet core switch has the following on-board ports: 14, 15, 16 and 17. The Ethernet
switch on the GbE fat pipe switch module uses on-board port 13.
Off-Board Path Device Settings
Modify off-board register values with the switch_reg or phy commands. See “phy” on
page 14-25 or “switch_reg” on page 14-27 for details.
Note: Proprietary information regarding register function or effect is not available in this user’s manual. Please
contact the switch manufacturer directly for details.
Tab le 4 -2
shows the Ethernet core switch default off-board ports.
Table 4-2: Ethernet Core Switch Off-Board Ports
PHY: Address:
Base Channel 1/TSEC2 0x2
Base Channel 2/TSEC3 0x3
TSEC2 (from CPU to Ethernet switch) 0x4
TSEC3 (from CPU to Ethernet switch) 0x5
Fat Pipe/TSEC4 0x6
Destination: Port:
Update Channel 7,8,9,10
Zone 3 4,6
AMC1-4 12,13,18,20,1
!