Emerson KAT4000 Network Hardware User Manual


 
Appendix B: Sensor Data Records
KAT4000 User’s Manual 10007175-02
B-42
Entity Instance 68
Sensor Initialization 5d Init Scanning
Init Sensor Type
Init Hysteresis
Init Thresholds
Sensor Scanning enabled
Sensor Capabilities 69 Ignore Sensor no
Auto Re-Arm enabled
Sensor Hysteresis hysteresis is settable/readable
Sensor Threshold Access threshold is settable/readable
Event Message Control global disable only
Sensor Type 03 Current
Event/Reading Type Code 01 Threshold
Assertion Event Mask 0800 Upper Non-Recoverable Going High supported
Deassertion Event Mask 4800 Lower Non-Recoverable Threshold comparison returned
Upper Non-Recoverable Going High supported
Discrete Reading Mask 3838 Upper Non-Recoverable Threshold settable
Upper Critical Threshold settable
Upper Non-Critical Threshold settable
Upper Non-Recoverable Threshold readable
Upper Critical Threshold readable
Upper Non-Critical Threshold readable
Sensor Units 1 00 Analog Data Format unsigned
Rate Unit none
Modifier Unit none
Percentage no
Sensor Units 2 - Base Unit 05 Amps
Sensor Units 3 - Modifier Unit 00 Unspecified
Linearization 00
M8a
M, Tolerance 40
B00
B, Accuracy 00
Accuracy, Accuracy Exp 00
R exp, B Exp c0
Analog Characteristic Flags 07
Nominal Reading 66
Normal Maximum bf
Normal Minimum 00
Sensor Maximum Reading ff
KAT4000 Records: Value: Parameter: Status: (continued)