Chapter 21-Collaboration ServerAdministration and Utilities
Polycom, Inc. 21-47
Using Hot Backup Triggers
Hot Backup is initiated by the slave MCU on detection of no response from the master MCU
on a “Keep Alive” operation. The Hot Backup triggers initiates the Hot Backup swap from
Master to Slave when the selected conditions on the Master MCU occur.
Guidelines
• Hot Backup triggers should be configured on both the Master and Slave MCUs.
•
Hot Backup triggers are not synchronized between the Master and Slave MCUs.
Configuring the Hot Backup Triggers
The Hot Backup triggers are configured in the Hot Backup dialog box for the Master MCU
when the Hot Backup feature is enabled.
To add the Hot Backup triggers to the Hot Backup configuration:
1
In the Hot Backup dialog box, expand the Trigger Hot Backup Triggers.