RealPresence Collaboration Server (RMX) 1500/2000/4000 Administrator’s Guide
24-2 Polycom, Inc.
The Hardware Monitor pane is displayed.
The Hardware Monitor pane displays the following Collaboration Server hardware
component’s status columns:
In the Hardware Monitor, Slots 1 & 2 may sometimes appear as duplicates in the Slot list.
Table 24-1 HW Monitor Pane Status Columns
Field Description
Slot Displays an icon according to the HW component type and the slot
number. The icon displays the hardware status as follows:
• An exclamation point (!) indicates errors in the HW component.
• Card icon with the reset button ( ) indicates that the HW component
is currently resetting.
• Card icon with diagnostic tools ( ) indicates that the HW component
is in diagnostic mode.
Type The type of hardware component card.
Status The current status of the HW component; Normal, Major, Critical,
Resetting, Diagnostics, or Empty.
Temperature Monitors the temperature of the hardware components; Normal, Major and
Critical.
Note: Critical condition invokes a system shut down.
Voltage The voltage threshold of the hardware component; either Normal or Major.