Polycom 1500 Server User Manual


  Open as PDF
of 1124
 
RealPresence Collaboration Server (RMX) 1500/2000/4000 Administrator’s Guide
22-18 Polycom, Inc.
3 To modify a flag value, double-click or select the flag and click the Edit Flag button.
4 In the New Value field, enter the flag’s new value.
5 Click OK to close the Update Flag dialog box.
6 Repeat steps 2–4 to modify additional flags.
7 Click OK to close the System Flags dialog box
USE_GK_PREFIX_FOR_PS
TN_CALLS
When set to YES the Gatekeeper Prefix is included in the
DTMF input string enabling PSTN participants to use the
same input string when connecting to an Collaboration Server
whether the Collaboration Server is a standalone MCU or part
of a DMA solution deployment.
Possible Values: YES / NO
Default: NO
For more information see "PSTN Dial-in Using GK Prefix” on
page 19-9.
USER_LOCKOUT If YES, a user is locked out of the system after three
consecutive Login failures with same User Name. The user is
disabled and only the administrator can enable the user
within the system.
Default: NODefault in Ultra Secure Mode: YES
For details, see "User Lockout” on page 23-24.
USER_LOCKOUT_DURATIO
N_IN_MINUTES
Defines the duration of the Lockout of the user.
Value: 0 - 480
0 means permanent User Lockout until the administrator re-
enables the user within the system.
Default: 0
USER_LOCKOUT_WINDOW
_IN_MINUTES
Defines the time period during which the three consecutive
Login failures occur.
Value: 0 - 45000
0 means that three consecutive Login failures in any time
period will result in User Lockout.
Default: 60
Table 22-1 System Flags – MCMS_PARAMETERS (Continued)
Flag Description
For flag changes (including deletion) to take effect, reset the MCU. For more information see
"Resetting the Collaboration Server (RMX)” on page 21-77.