Chapter 22-System Configuration Flags
Polycom, Inc. 22-5
ENFORCE_SAFE_UPGRAD
E
When set to YES this flag enables the Collaboration Server
system to notify users when an incorrect version upgrade/
downgrade or upgrade/downgrade path is selected.
When set to NO, after initiating an upgrade or downgrade
software installation, the Collaboration Server activates a fault
alert in the Faults List: “Warning: Upgrade started and SAFE
Upgrade protection is turned OFF” and the upgrade/
downgrade process continues.
Range: YES / NO
Default: YES
ENABLE_SENDING_ICMP_
DESTINATION_UNREACHA
BLE
When set to YES, this flag allows the RMX to send ICMP
Destination Unreachable Messages (ICMP message type #3)
messages. For more information, see "Internet Control
Message Protocol (ICMP)” on page 23-51.
EXT_DB_IVR_PROV_TIME_
SECONDS
When an Entry Queue is set as IVR Service Provider for the
DMA, the value here indicates the time interval in seconds in
which the database is accesses for the ID.
Default: 300
FORCE_CIF_PORT_ALLOC
ATION
Sets the MCU to allocate one CIF video resource to an
endpoint, regardless of the resolution determined by the
Conference Profile parameters. You can specify the endpoint
types for which resource allocation can be forced to CIF
resource, enabling other types of endpoints to use higher
resolutions in the same conference.
Enter the product type to which the CIF resource should be
allocated. Possible values are:
• CMA Desktop - for CMA desktop client
• VSX nnnn - where nnnn represents the model number for
example, VSX 8000.
FORCE_STRONG_PASSWO
RD_POLICY
When set to YES(default when
ULTRA_SECURE_MODE=YES), implements the Strong
Password rules. For more details, see “Changing a User’s
Password” on page 15-4.
Default: NO
FORCE_SYSTEM_BROADC
AST_VOLUME
If set to YES, the level of broadcasting volume of the
connected participant is value taken from the system flag
SYSTEM_BROADCAST_VOLUME.
If set to NO (default), the broadcasting volume level is 5.
FORCE_SYSTEM_LISTENIN
G_VOLUME
If set to YES, the level of listening volume of the connected
participant is value taken from the system flag
SYSTEM_LISTENING_VOLUME.
If set to NO (default), the listening volume level is 5.
Table 22-1 System Flags – MCMS_PARAMETERS (Continued)
Flag Description